Search results for "Single shot"

showing 9 items of 9 documents

Optical sectioning microscopy through single-shot Lightfield protocol

2020

Optical sectioning microscopy is usually performed by means of a scanning, multi-shot procedure in combination with non-uniform illumination. In this paper, we change the paradigm and report a method that is based in the light field concept, and that provides optical sectioning for 3D microscopy images after a single-shot capture. To do this we fi rst capture multiple orthographic perspectives of the sample by means of Fourier-domain integral microscopy (FiMic). The second stage of our protocol is the application of a novel refocusing algorithm that is able to produce optical sectioning in real time, and with no resolution worsening, in the case of sparse f luorescent samples.We provide the…

FiMicGeneral Computer ScienceOptical sectioningComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION02 engineering and technology3d microscopy01 natural sciences010309 opticsOptics0103 physical sciencesMicroscopyGeneral Materials ScienceProtocol (object-oriented programming)Fourier integral microscopebusiness.industryResolution (electron density)Orthographic projectionGeneral EngineeringSingle shotfourier lightfield microscopeGPU computingÒptica021001 nanoscience & nanotechnologySample (graphics)Microscòpialightfield microscopeoptical sectioninglcsh:Electrical engineering. Electronics. Nuclear engineering0210 nano-technologybusinesslcsh:TK1-9971
researchProduct

The Lightfield Microscope Eyepiece

2021

Lightfield microscopy has raised growing interest in the last few years. Its ability to get three-dimensional information about the sample in a single shot makes it suitable for many applications in which time resolution is fundamental. In this paper we present a novel device, which is capable of converting any conventional microscope into a lightfield microscope. Based on the Fourier integral microscope concept, we designed the lightfield microscope eyepiece. This is coupled to the eyepiece port, to let the user exploit all the host microscope’s components (objective turret, illumination systems, translation stage, etc.) and get a 3D reconstruction of the sample. After the optical design, …

FiMicMicroscopeComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONTP1-1185Translation (geometry)BiochemistryAnalytical Chemistrylaw.inventionEyepieceOpticslawlightfield eyepieceMicroscopyplenoptic eyepieceElectrical and Electronic EngineeringInstrumentationLightingFourier integral microscopeMicroscopylightfield microscopybusiness.industryCommunicationChemical technology3D reconstructionSingle shotTime resolutionSample (graphics)Atomic and Molecular Physics and OpticsÒptica Aparells i instrumentsMicroscòpia3D microscopybusinessSensors
researchProduct

Depth rendering of large incoherent scenes from integral images

2016

Integral imaging is a technique that provides the spatial and angular information of three-dimensional (3D) scenes through a single shot. Taking advantage of this capability, different applications have been developed. Some of these applications are the 3D display and digital post-processing, in particular depth-reconstruction from integral images.

Integral imagingbusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONSingle shotIntegral photographyStereo displayRendering (computer graphics)symbols.namesakeThree dimensional imagingFourier transformComputer graphics (images)symbolsComputer visionArtificial intelligencebusinessMathematics
researchProduct

Mathematical models for the diffusion magnetic resonance signal abnormality in patients with prion diseases

2014

In clinical practice signal hyperintensity in the cortex and/or in the striatum on magnetic resonance (MR) diffusion-weighted images (DWIs) is a marker of sporadic Creutzfeldt–Jakob Disease (sCJD). MR diagnostic accuracy is greater than 90%, but the biophysical mechanisms underpinning the signal abnormality are unknown. The aim of this prospective study is to combine an advanced DWI protocol with new mathematical models of the microstructural changes occurring in prion disease patients to investigate the cause of MR signal alterations. This underpins the later development of more sensitive and specific image-based biomarkers. DWI data with a wide a range of echo times and diffusion weightin…

MalePathologysCJD sporadic Creutzfeldt–Jakob diseaseROI region of interestPrion diseasePrPSc prion protein scrapieElectroencephalographyFOV field of viewlcsh:RC346-429Prion DiseasesADC apparent diffusion coefficientTI inversion timeRPE rapidly progressive encephalopathyAged 80 and overTE echo timeBrain Mappingmedicine.diagnostic_testBrainRegular ArticleMiddle AgedBIC Bayesian information criterionTR repetition timemedicine.anatomical_structureNeurologylcsh:R858-859.7FemaleMPRAGE magnetization-prepared rapid acquisition gradient-echoAbnormalitySS-SE single shot spin-echoAdultmedicine.medical_specialtyCognitive NeuroscienceCreutzfeldt–Jakob diseaseCNR contrast to noise ratioEPI echo-planar imagingNeuropathologyPrPC prion protein cellularGrey matterSpongiform degenerationlcsh:Computer applications to medicine. Medical informaticsEEG electroencephalogramDiffusion MRINeuroimagingImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imaginglcsh:Neurology. Diseases of the nervous systemAgedCJD Creutzfeldt–Jakob diseaseGSS Gerstmann–Sträussler–Scheinker syndromebusiness.industryDWI diffusion weighted imagingDiffusion MRI; Biophysical models; Creutzfeldt-Jakob disease; Prion disease; Spongiform degenerationMagnetic resonance imagingModels TheoreticalHyperintensityCreutzfeldt-Jakob diseaseDiffusion Magnetic Resonance ImagingNeurology (clinical)businessBiophysical modelsDiffusion MRINeuroImage: Clinical
researchProduct

Robust quantum control by a single-shot shaped pulse

2013

Considering the problem of the control of a two-state quantum system by an external field, we establish a general and versatile method allowing the derivation of smooth pulses which feature the properties of high fidelity, robustness, and low area. Such shaped pulses can be interpreted as a single-shot generalization of the composite pulse-sequence technique with a time-dependent phase.

PhysicsAtomsLimitsSingle shotInversionGeneral Physics and AstronomyQuantum controlLaserMoleculesLaserTopology01 natural sciencesNMR010305 fluids & plasmaslaw.inventionComposite pulsesHigh fidelitylaw0103 physical sciencesQuantum systemExternal fieldInduced population transfer010306 general physicsBroad band excitation
researchProduct

Single-shot generation and detection of a two-photon generalized binomial state in a cavity

2006

A "quasi-deterministic" scheme to generate a two-photon generalized binomial state in a single-mode high-Q cavity is proposed. We also suggest a single-shot scheme to measure the generated state based on a probe two-level atom that "reads" the cavity field. The possibility of implementing the schemes is discussed.

PhysicsQuantum PhysicsPhotonField (physics)Binomial (polynomial)Single shotQUANTUM INFORMATIONFOS: Physical sciencesPhysics::OpticsELECTROMAGNETIC-FIELDState (functional analysis)PHOTONSMeasure (mathematics)GeneralLiterature_MISCELLANEOUSAtomic and Molecular Physics and OpticsATOMSRADIATION-FIELDTwo-photon excitation microscopyQuantum mechanicsAtomQuantum Physics (quant-ph)PHASE PROPERTIESENTANGLEMENTPhysical Review A
researchProduct

Lightfield microscopy, an emerging tool for real-time 3D imaging

2020

Integral, or lightfield, microscopy offers the possibility of capturing and processing in real time multiple views of 3D fluorescent samples captured with a single shot. In this contribution we review the recent advances in lightfield microscopy and enunciate the forthcoming challenges.

Point spread functionComputer sciencebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONSingle shotIntegral photographyGeneralLiterature_MISCELLANEOUSlaw.inventionOpticsConfocal microscopylawMicroscopybusinessMultiple viewImaging and Applied Optics Congress
researchProduct

Alignement moléculaire par impulsions laser ultrabrèves : Mesures & Applications

2009

The interaction of an intense ultrashort laser pulse with a molecular sample leads, after the end of the pulse, to molecular alignment at specific time under field-free conditions. This thesis is dedicated to the measurements and applications of this effect. The degree of alignment is determined through the variation of the refractive index induced by the rearrangement of the molecular dipoles. A two-dimensional technique allowing to measure molecular alignment on a single-shot basis is reported in this document. The alignment is then exploited in order to determine physical quantities which are usually difficult to estimate through others methods. The "cross-defocusing technique" has been …

[PHYS.PHYS.PHYS-OPTICS] Physics [physics]/Physics [physics]/Optics [physics.optics][PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]Biréfringence[ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]Molecular alignmentRotational coherenceAlignement moléculaireDiagnostique optiqueMesure d'indice Kerr optique d'ordre élevéUltrashort pulsesOptical diagnosticSingle shot measurementCohérence rotationnelleMeasurement of high order optical Kerr effectPump-probe experimentImpulsions ultrabrèvesMesure monocoupTechniques pompe-sonde
researchProduct

319: Single shot spinal anaesthesia with low dose hyperbaric bupivacaine (3.75 mg), for hip fracture repair surgery in the elderly

2007

medicine.medical_specialtyAnesthesiology and Pain MedicineHyperbaric bupivacainebusiness.industryAnesthesiaLow dosemedicineSingle shotSpinal anesthesiaGeneral MedicineHip fracture repairbusinessSurgeryRegional Anesthesia and Pain Medicine
researchProduct